Article Id: #111     Viewed: 258 times     Last updated on: 16 Jun 2008     Article Category: DSLR Plug-in    
[Print]  [Email]
This is a known problem affecting v4.59 through v4.61. It is fixed in v4.62.

Work-around: patch the value in the registry. Unfortunately you can only do this when MaxIm DL is shut down, or at least before opening the MaxIm DL window:

1) click Start > Run...
2) type REGEDIT and click OK
3) in the left-hand pane, navigate down to and click on
HKEY_CURRENT_USERSoftwareDiffraction LimitedMaxIm CCD 4
CurrentVersion
4) in the right-hand pane, double-click on D3236_SEQ_SYNCINTERVAL
5) type in the desired value and click OK
6) select Exit from the Registry menu